Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the rocket domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /www/wwwroot/profiber.com.vn/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the wordpress-seo domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /www/wwwroot/profiber.com.vn/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time được gọi không chính xác. Tải bản dịch cho miền hello-elementor được kích hoạt quá sớm. Đây thường là dấu hiệu cho thấy một số mã trong plugin hoặc chủ đề chạy quá sớm. Bản dịch phải được tải tại hành động init hoặc sau đó. Vui lòng xem Hướng dẫn Debug trong WordPress để biết thêm thông tin. (Thông điệp này đã được thêm vào trong phiên bản 6.7.0.) in /www/wwwroot/profiber.com.vn/wp-includes/functions.php on line 6114
Data Center - Profiber
Phương tiện truyền thông tin tức

Hệ thống dây phòng trung tâm dữ liệu bao gồm hai phần: hệ thống dây mạng SAN và hệ thống cáp mạng. Trong kỹ thuật hệ thống máy tính, phải tôn trọng phòng trong quy hoạch và thiết kế hệ thống dây điện thống nhất, định tuyến cầu nối dây phải được tích hợp vào phòng máy và các loại đường ống, cầu nối khác, để đảm bảo việc triển khai hệ thống là hợp lý và có trật tự trong phòng . Kỹ thuật cáp trung tâm dữ liệu với tính linh hoạt, khả năng mở rộng để đạt được quản lý dây dự phòng, toàn bộ hệ thống cáp có cấu trúc phải là một giải pháp toàn diện để tránh sự xuất hiện của một điểm lỗi.

Được thông qua: plug and play, mật độ cao, có thể mở rộng, các giải pháp hệ thống cáp kết thúc trước, quản lý hệ thống mô-đun và lắp ráp trước có thể giảm thời gian cài đặt, nhận ra mạng cáp quang trung tâm dữ liệu di chuyển, thêm và thay đổi nhanh hơn. hệ thống có thể được sử dụng trong nhiều loại sản phẩm sợi quang có thể được sử dụng trong đầu nối sợi quang suy hao thấp và sợi không nhạy uốn cong (bán kính uốn 7,5mm), để đạt được hiệu suất uốn và suy giảm sợi quang đường trục nhỏ hơn.

Data Center Solution

Dây nhảy quang được sử dụng để thực hiện kết nối hoặc kết nối chéo trong hệ thống cáp có cấu trúc, thường được sử dụng cùng với các mô-đun quang trong trung tâm dữ liệu để đạt được khả năng kết nối giữa các thiết bị.

 

Giải pháp kết nối mô-đun quang 10G

Now, most of data centers are still deployed 10G Ethernet, and the development of optical module is from the larger XFP optical module gradually developed into the current mainstream SFP + optical module. The port of SFP+ optical module is duplex LC interface, thus the SFP+ optical module can achieve interconnection via duplex LC fiber optic jumper of two switches, routers, servers or network interface cards. ProFiber VietNam supplies a verity of high quality duplex LC fiber optic jumpers, optical cable are available in single-mode and multi-mode that applied to various 10G network interconnect environment.

Data Center Solution

Giải pháp kết nối mô-đun quang 40G

After several years of development, 40G Ethernet is now sweeping the world, 40G QSFP + optical module has become the rising star of the optical module market. Unlike 10G SFP+ optical module, the port of 40G QSFP+ optical module is mostly MPO/MTP interface that requires MPO/MTP fiber optic jumper to achieve interconnection. ProFiber VietNam provides single/mulit-mode MPO/MTP fiber optic jumper, the type of jacket are availble in PVC, LSZH, OFNP etc. In addition, we also offers MPO/MTP distribution box to help you upgrade easily to 40G/100G network.

Data Center Solution
Lưu ý: kết nối đường dài giữa các mô-đun quang 40G QSFP+ thường sử dụng sợi quang đơn mode, do đó, mô-đun quang 40G QSFP+ trong ứng dụng truyền dẫn đường dài là giao diện LC song công để nhận ra kết nối với việc sử dụng dây nhảy quang đơn mode LC song công . Tuy nhiên, mô-đun quang 40GBASE-PLRL4 QSFP+ thường được sử dụng với dây nhảy quang đơn mode MPO/MTP 12 lõi.
Như chúng ta đã biết, một cổng 40G QSFP+(4 x 10 Gbps)có thể được cấu hình thành 4 kênh sợi quang SFP+, vì vậy chúng ta cũng có thể sử dụng dây nhảy quang MPO/MTP-LC để dễ dàng kết nối với thiết bị mạng 10G và 40G.
Data Center Solution

Giải pháp kết nối mô-đun quang 100G

2016 can be said to be a milestone in the 100G Ethernet, in this year, CXP, CFP, CFP2, CFP4, QSFP28 and other 100G optical modules emerge in endlessly in the market. As a professional supplier, ProFiber VietNam offers the following 100G interconnect solutions:

Liên thông giữa các module quang CXP/CFP

24-core MPO/MTP fiber optic jumper supplied by ProFiber VietNam is an ideal solution to the interconnection between CXP/CFP optical modules, the diagram below shows the detailed connecting program:
Data Center Solution

Kết nối giữa các mô-đun quang QSFP28

Nguyên lý hoạt động của mô-đun quang QSFP28 tương tự như 40G QSFP +, nhưng điểm khác biệt là tốc độ truyền của mỗi kênh sợi quang của mô-đun quang QSFP28 là 25Gbps, tốc độ truyền của bốn kênh sợi quang có thể đạt tới 100G. Cần có bộ nhảy quang MPO/MTP 12 lõi để đạt được liên kết sợi quang QSFP28 đa chế độ và cần có bộ nhảy quang đơn mode LC song công để đạt được liên kết sợi quang QSFP28 một chế độ (sử dụng mô-đun quang 100GBASE-LR4 QSFP28) .

Kết nối giữa CXP/CFP và module quang 10G SFP+

Do module quang CXP/CFP sử dụng các kênh sợi quang 10 x 10Gbps để truyền tải 100G nên chúng ta có thể sử dụng dây nhảy quang MPO/MTP (24 lõi) LC để kết nối với CXP/CFP và module quang 10G SFP+ để thực hiện kết nối giữa thiết bị mạng 100G và 10G.
Data Center Solution